5. Alignment and Adjustments

PRECAUTION

1.High voltage is present at the high voltage terminals during any cook cycle.

2.It is neither necessary nor advisable to attempt measurement of the high voltage.

3.Before touching any oven components or wiring, always unplug the oven from its power source and discharge the high voltage capacitor.

5-1 High Voltage Transformer

1.Remove connectors from the transformer terminals and check continuity.

2.Normal resistance readings are as follows:

 

MODEL

CE745GR

 

 

 

 

 

 

 

 

 

 

 

Secondary

 

103.2Ω ¡

10%

 

Filament

 

Shows Continuity

Primary

 

1.61Ω ¡

10%

 

 

 

 

 

 

(Room temperature = 20ûC)

Filament Terminals

Primary

Terminals

5-2 Low Voltage Transformer

1.The low voltage transformer is located on the control circuit board.

2.Remove the low voltage transformer from the PCB Ass'y and check continuity.

3.Normal resistor reading is shown in the table.

Terminals

Resistance

 

 

1~2(Input)

1149Ω

4~5(Output17V)

12.26Ω

7~8(Output2.9V)

2.574Ω

 

 

5-3 Magnetron

1. Continuity checks can indicate only an open

Magnetron Antenna

filament or a shorted magnetron. To diagnose anGasket Plate open filament or shorted magnetron :

2.Isolate the magnetron from the circuit by disconnecting its leads.

3.A continuity check across the magnetron filament terminals should indicate one ohm or less.

4.A continuity check between each filament terminal and magnetron case should read open.

Cooling Fins

Samsung Electronics

5-1

Page 11
Image 11
Samsung CE745GR service manual Alignment and Adjustments, High Voltage Transformer, Low Voltage Transformer, Magnetron