gas conversion
Ŷ7DNHSUHFDXWLRQVRQWKHRSHUDWLRQVDQGDGMXVWPHQWVWREHFDUULHGRXWZKHQ
FRQYHUWLQJIURPRQHJDVWRDQRWKHU Ŷ$OOZRUNPXVWEHFDUULHGRXWE\DTXDOL¿HGWHFKQLFLDQ
1 | Ŷ%HIRUH\RXEHJLQWXUQRIIWKHJDVDQGHOHFWULFLW\VXSSO\WRWKHDSSOLDQFH |
&KDQJHWKHLQMHFWRURIWKHEXUQHUV | |
5HPRYHWKHSDQVXSSRUW%XUQHUOLGDQG)ODPHVSUHDGHU |
Injector |
8QVFUHZWKHLQMHFWRUXVLQJDPPER[VSDQQHUDQGUHSODFHLWZLWK WKHVWLSXODWHGLQMHFWRUIRUQHZJDVVXSSO\VHH 3DJH6
&DUHIXOO\UHDVVHPEOHWKHDOOFRPSRQHQWV
$IWHULQMHFWRUVDUHUHSODFHGLWLVDGYLVDEOHWRVWURQJO\WLJKWHQWKH injector in place.
2Adjustment of minimum level of the flame
Turn the taps down to minimum.
Control handle
Tap Sealing ring
Tap
E\SDVVVFUHZ
Remove the control hands from taps. Adjusting by pass screw
‐ For converting ‘natural’ gas G20 into ‘liquid’ gas G30 the screw must be screws down fully tight
‐ For converting back from G30 into G20, please rotate the screw in opposite direction to adjust the minimum level
‐ Finally check the flame does not go out when quickly turning the tap from the maximum position to the minimum position.
Install the control handles on the taps.
Ŷ'RQRWGLVPDQWOHWKHWDSVKDIW LQWKHHYHQWRIDPDOIXQFWLRQ FKDQJHWKHZKROHWDS
Ŷ%HIRUHSODFLQJWKHEXUQHUV EDFNRQWKHWRSSODFHPDNHVXUH
WKDWWKHLQMHFWRULVQRWEORFNHG Ŷ$IXOORSHUDWLRQDOWHVWDQGDWHVW
IRUSRVVLEOHOHDNDJHVPXVWEH FDUULHGRXWDIWHUJDVFRQYHUVLRQ VXFKDVVRDSZDWHURUJDV GHWHFWRU
Ŷ$IWHUFRPSOHWLQJFRQYHUVLRQ DTXDOL¿HGWHFKQLFLDQRULQVWDOOHU KDVWRPDUN³9´RQWKHULJKWJDV FDWHJRU\WRPDWFKZLWKWKH VHWWLQJLQUDWLQJSODWH 5HPRYHWKHSUHYLRXV VHWWLQJ³9´PDUN
|
| 0359CO1395 |
|
|
|
Model: | S/N: |
|
G20/20mbar |
Qn G20: G30: G31:
G20/20mbar G30/29mbar G31/37mbar GB Cat.: II 2H3+
23technical instruction