STATUS INDICATOR
ENGLISH
Mode | Status | Display | Function |
Status | Compressor On |
| This icon indicates that the compressor in the outdoor |
|
|
| unit is running. |
|
|
|
|
|
| This icons indicate that the backup heater of the unit | |
| On |
| is operating, when there is a high demand for heating |
|
|
| capacity. The backup heater provides extra heating |
|
|
| capacity in case of low ambient outdoor temperature |
|
|
| (high heating load). |
|
|
|
|
| Booster heater |
| This icon indicates that the booster heater is active. |
| On |
| The booster heater provides auxiliary heating for the |
|
|
| domestic hot water tank. The booster heater is located |
|
|
| in the domestic hot water tank. The icon is not used |
|
|
| when the domestic hot water tank is not installed. |
|
|
|
|
| Solar thermal |
| It indicates when the solar panel is powered on. DHW |
| panel On |
| mode is stopping while solar panel is on in order to save |
|
|
| your energy cost. |
|
|
|
|
| Back up boiler |
| The Back up boiler shall start to work as soon as |
| On |
| outdoor temperature reach to the targeted temperature. |
|
|
| Users can adjust the temperature to allow the back up |
|
|
| boiler work. The icon shall not be displayed without the |
|
|
| Installation of the back up boiler. |
|
|
|
|
| Water pump On |
| This icon indicates that the circulation pump is active. |
|
|
|
|
| Domestic water |
| This icon indicates when the domestic water heating |
| On |
| mode is operating. |
|
|
|
|
| Defrost |
| This icon indicates that the defrost mode is active. |
| operation On |
|
|
|
|
|
|
| Anti freezing |
| The system automatically maintains the water |
| operation On |
| temperature above a freezing point to prevent from |
|
|
| |
|
|
|
|
| Sanitary |
| This function disinfects the DHW tank by periodically |
| operation On |
| heating the domestic water to a specific temperature. |
|
|
|
|
Checking the function _13