INSTALLATION PROCEDURE
1. Connect the water pipe with coupler and tap.1)Close the main water tap.
2)Connect coupler “A” to the tap.
3)Every join should be protected with sealing tape.
WARRANTY INFORMATION
This water line installation is not covered by the fridge/freezer or ice maker manufacturer's warranty.
Follow these instructions carefully to minimise the risk of expensive water damage.
CAUTION
The water tube must be connect-
ed to the cold water pipe. If it is connected to the hot
water pipe, it may cause the purifi-
er to malfunction.
COUPLER “A”
Note:
If the coupler does not fit on the existing
tap, consult the nearest authorised ser-TAP vice dealer and purchase the right cou-
plers for the installation.
2. Select the location where the purifier is to install. (Model with the purifier)
1)Cut the water tube attached to the purifi- er to the appropriate length after measur- ing the distance between the purifier and the cold water tap.
2)If you wish to reassemble the water inlet and outlet sides of the purifier during purifier installation, see the reference illustration.
COUPLER
90DEGREE
WATER INLET SIDE SQUARE
OF PURIFIER
WATER TUBE | REFERENCE |
PURIFIER
OUTLET SIDE OF
PURIFIER
1)Open the main water tap to check whether water is running through the water tube on the water inlet side of the purifier.
2)If water does not come out through the tube, check whether the tap is open.
3)Leave the tap open until clean water is running out and any residual matter that built up during manufacturing has been removed.
WATER TUBE
PURIFIER
WATER
OUTLET SIDE OF PURIFIER
12