6 FUNCTION | 7 DC IRIS Level Bar | |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
If multiple cameras are connected to such as a sequential switcher in auto switch mode, the camera in the internal sync mode occurs a skip every time it moves to other scene. However, this can be solved by positioning the L/L switch to EXT and using the level bar to adjust the vertical sync phasing.
-INT: It operates in the internal synchronization mode.
-EXT: it operates in the power synchronization mode.
※If your camera uses DC 12V for power source, it operates in the internal mode regardless of the position (EXT/INT) of the L/L switch.
10
Used to adjust the iris level of this level bar using a screwdriver.
-
-Clockwise: Increases the luminance level.
-The IRIS range of the DC lens is about between 80IRE and120IRE. In other words, the DC lens adopts a variable range limitation system, rather than IRIS Full Open/Close system.
-Depending on the type of the lens used that allows setting the value below 75 IRE may cause IRIS hunting. Therefore, make sure that the range is set to an appropriate level (higher than 80 IRE).
8Video Out Port
Connected to the Video Out port of a monitor. The video signal is output via this port.