Summary

The Wall Mounted Adaptor (SADT-100WM) is used for the installation of the Smartdome Camera (indoor or outdoor housing) on walls.

Precautions Before Installation

Make sure that the proposed location can support the combined weights of the Wall Mounted Adaptor, Outdoor Housing and Smartdome Camera (about 8 kg).

This product is designed to use M10 anchor bolts or nuts.

When installing the product on a concrete wall, use M10 anchor bolts/nuts together with plain and spring washers.

Each anchor bolt must be capable of withstanding an extraction force of 700 kg.

When installing the product outdoors, use interlocking devices made of stainless steel.

The Wall Mounted Adaptor may be installed directly on a wall or in conjunction with the Corner Mounted Adaptor (SADT-110CM) or the Pole Mounted Adaptor

(SADT-100PM), in which cases a PG-13.5 cable gland should be used.

This goods should only be installed by a qualified technician using approved materials and wiring practices in accordance with national, state, and local electrical code.

Installation

1

Select a location that will support four times the total weight of the

 

product to be installed (about 32 kg).

 

 

Use the Back Plate to mark the positions of the M10 anchor

 

2

 

bolts/nuts on the wall, drill the holes and install the anchor

 

 

bolts/nuts.

GB

When installing in the corner of a wall, use the Corner Mounted Adaptor (SADT-110CM). When installing on a pole, use the Pole Mounted Adaptor (SADT-100PM).

3 If the cable pipe is installed inside the wall:

1)Pull the power cable, video-out cable and communications cable out through the holes of the Back Plate and Wall Mounted Adaptor. Take care not toavoid damageto the cable sleeving.

When installing with the Corner Mounted Adaptor or the Pole Mounted Adaptor, use a PG-13.5 Cable Gland for watertightness.

If the cable pipe is installed on the wall:

1)Make a hole of 21mm in diameter on the outside of the pipe (on the side and near the tip) and install a PG13.5 cable gland.

2)Pull the cables out to the Wall Mounted Adaptor through the cable gland.

Positions for the hole (unit: mm)

1

2