setup

If <BACKLIGHT> is set to <BLC>, the MASK AREA function is not available.

EXT : The interface to an external alarm enables an automatic switch between DAY and NIGHT mode.

MIf you use an infrared light source while in AUTO mode, this may cause a failure in AUTO SWITCH or AUTO FOCUS.

WHITE BAL

If you need to adjust the color according to the ambient illumination, you can use the <WHITE BAL> function.

Illumination is generally referred to as color temperature, which is represented in a measurement of kelvin (K). Color temperatures for ordinary lighting are as follows:

In the <WHITE BAL> menu, you can set a mode for correcting the <WHITE BAL>.

-ATW1,2 : If you set the <WHITE BAL> menu to <ATW1> or <ATW2> mode, this will monitor the change of the color temperature to correct the <WHITE BAL> as needed.

The following color temperature ranges are assured in individual modes:

ATW1 : 2500K ~ 9300K ( 1)

ATW2 : 2000K ~ 10000K

(suitable to sodium light source) ( 2)

10000K

Blue sky

9000K

Rainy

8000K

 

7000K

 

6000K

Cloudy

 

5000K

Partly Cloudy

4000K

Sunny

3000K

Fluorescent lamp

 

2000K

Halogen lamp

1000K

Candlelight

Tungsten lamp

 

1 : With <ATW1> mode active in a color temperature environment ranging beyond between 2500K and 9300K, a proper white balance value may not be produced; if this is the case, you are recommended to use <ATW2> mode.

2 : With <ATW2> mode active in a mostly single color environment, the display color and the actual one may differ; so select a mode as appropriate to your color temperature environment.