ADAPTER CONNECTION

INITIAL SETTING

CAMERA ADDRESS SETUP

Use SW701, SW702, or 703 for Camera Address setup. You may allocate up to 255 addresses by using SW701 to set the 3rd digit, SW702 the 2nd digit, and SW703 the 1st digit.

EX) In case of Camera Address 1, see the following figure for setup.

SCC-C6405(P) Adapter BOARD

E

SW701SW702SW703

Setting communication Protocol

 

 

 

Use number 1~4 PIN of SW704 to set communication Protocol.

PIN

PIN1

PIN2

PIN3

 

PIN4

 

A : SAMSUNG HALF

 

 

Comp

 

 

 

 

A

OFF

OFF

OFF

 

OFF

 

B : SAMSUNG FULL

 

 

B

ON

OFF

OFF

 

OFF

 

 

 

 

 

C

OFF

ON

 

OFF

 

OFF

 

 

 

 

 

D

ON

ON

 

OFF

 

OFF

 

 

SEE INSTRUCTION MANUAL

 

 

 

 

 

 

 

 

 

E

OFF

OFF

ON

 

OFF

 

 

ON 1 2 3 4 5 6 7 8

F

ON

OFF

ON

 

OFF

 

 

 

 

SW704

 

 

 

(x100)

(x10)

(x1)

G

OFF

ON

 

ON

 

OFF

 

 

 

 

 

 

 

 

 

H

ON

ON

 

ON

 

OFF

 

 

SW701 SW702 SW703

I

OFF

OFF

OFF

 

ON

 

 

 

 

 

J

ON

OFF

OFF

 

ON

 

 

 

 

 

K

OFF

ON

 

OFF

 

ON

 

 

 

 

 

L

ON

ON

 

OFF

 

ON

 

 

 

 

 

M

OFF

OFF

ON

 

ON

 

 

 

 

 

N

ON

OFF

ON

 

ON

 

 

 

 

 

O

OFF

ON

 

ON

ON

 

 

(BOTTOM VIEW)

P

ON

ON

 

ON

 

ON

 

 

 

 

 

 

 

 

 

Baud Rate Setting

 

 

 

 

 

 

 

 

Use PIN 5 and 6 of SW704.

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW 704

 

 

 

 

 

 

 

 

BAUD RATE

 

 

 

PIN 5

 

PIN 6

 

 

4800 BPS

 

 

 

 

ON

 

ON

 

 

9600 BPS

 

 

 

 

OFF

 

ON

 

 

19200 BPS

 

 

 

ON

 

OFF

 

1-9

38400 BPS

 

 

 

OFF

 

OFF

1-10

 

 

 

 

 

 

 

 

 

 