output format

WIEGAND OUTPUT

Timing Diagram

 

100us

 

 

 

 

 

 

 

1ms

 

 

 

 

 

5V

DATA-0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0V

 

 

 

 

 

 

 

5V

DATA-1

 

 

 

 

 

 

0V

 

 

 

 

 

 

 

 

1

2

3

n-2 n-1

n

*n : 26

LOGIC

0

1

1

1

0

0

 

Data Type

Bit 1 : Even Parity (bit 2 ~ bit 13)

Bit 2 ~ 9 : Facility Code (000 ~ 255)

Bit 10 ~ 25 : ID Number (00000 ~ 65,535)

Bit 26 : Odd Parity (bit 14 ~ bit 25)