Chapter 7. Product Specification
ITEM DESCRIPTION
INTERFACE (RS-485) CONNECTOR TYPE : 4PTERMINALTYPE
PORT: 1 PORT
BAUD RATE : 4,800/9,600/19,200/38,400bps
INTERFACE (RS-232C) CONNECTOR TYPE : D-SUB 9P
PORT: 1 PORT
BAUD RATE : 600/1,200/2,400/4,800/
9,600/19,200/38,400/57,600bps
LCD PANEL 5.7” GRAPHIC PANEL(320X240line) + TOUCH
PANEL
VIEWING ANGLE : LEFT(39º),RIGHT(32º),
REAR(10º), FRONT(30º)
INCLINATION ANGLE : MIN(8.4º), MAX(15.9º)
LED MONITOR, CAMERA, MULTIPLEXER, DVR
PAN/TILT& PAN : LEFT/RIGHT
LENS CONTROL TILT: UP/DOWN
IRIS : CLOSE/OPEN
FOCUS : FAR/NEAR
ZOOM : TELE/WIDE
PRESET, PATTERN, AUTO PAN, SCAN
DVR CONTROL SW: RW, STOP, PLAY, FF, REC.
JOG/SHUTTLE : FORWARD/REVERSE,
PLAY/REVERSE PLAY/FF/RW
POWER DC12V, 600mA
POWER CONSUMPTION
BELOW3W
DIMENSIONS (WxHxD) NET: 490 x 197x 282
PACKAGE : 496 x 206x 288
WEIGHT(kg) NET: 1.36Kg
PACKAGE : 2.6Kg
Chapter 8. Q & A

The system keyboard communication is not worked.

- Check the RS-485 communication line.
- Check the address setup of system keyboard.
Refer to “RS-485 COMMUNICATION SETUP(GB-12)” of
“Chapter 5. Menu setting” for the method of address setup.

The password in the screen of system log in is lost.

- Apply the power in the state of pressing the “MENU” and
“ENTER” button of system keyboard at the same time.
- Press buttons until the “Beep” sounds.
- System is reset to the factory default with a “Beep” sound.
- Log in after the completion of reset.
Refer to “Log-in (GB-8)” of “Chapter 4. Instructions” for the
method of login.
Replace the LCD panel when its expected life is over.
GB-17