Alignment and Adjustments
4-1-3 Adjustment in Option Mode
This adjustment is necessary whenever the EEPROM is replaced. Input data (as marked on the back cabinet).
ADJUSTMENT
PATTERN
OPTION
RESET
Select “SET OPTION” by pressing the Channel ▼ key twice.
ADJUSTMENT
PATTERN
OPTION
RESET
Press the Volume +, - keys to enter the set Option mode.
BYTE 0 : 0 0
Press MENU to go back to the factory mode.
ADJUSTMENT
PATTERN
OPTION
RESET
Select RESET with channel ▼ key.
ADJUSTMENT
PATTERN
OPTION
RESET
Press volume + key.
POWER
OFF
4-1-4 Service Mode Adjustments
ADJUSTMENT
PATTERN
OPTION
RESET
1.The Pattern Adjustment is done only in the factory. Do not attempt to readjust it.
2.Refer to
3.Set OPTION data.
4-1-5 Service Mode Adjustment Ratings
No | Item | Function | Range | Initalized |
MICOM Data | ||||
|
|
|
|
|
1 | AGC | RF AGC Adjustment | 0~63 | 50 |
2 | VCO | PIF VCO Adjustment | 0~127 | 63 |
3 | SCT | 0~63 | 48 | |
4 | SCR | 0~27 | 13 | |
5 | STT | 0~27 | 7 | |
6 | RC | 0~255 | 0 | |
7 | GC | 0~255 | 0 | |
8 | BC | 0~255 | 0 | |
9 | SVC | Input a Horiz line pattern |
|
|
10 | GG | 0~255 | 127 | |
11 | BG | 0~255 | 127 | |
12 | SBT | 0~63 | 31 | |
13 | VA | VERTICAL SIZE Adjustment | 0~63 | 39 |
14 | VS | VERTICAL CENTER Adjustment | 0 | 0 |
15 | HS | HORIZONTAL Phase Adjustment | 0~31 | 15 |
16 | SS | 0~31 | 4 | |
|
|
|
|
|
Note : The initial MICOM data values take effect when IC902 is replaced.