DIMENSIONAL DATA

DIMENSIONAL DATA

Indoor Unit: THS3632

Dimension : inch

Indoor Unit: THS3632 Drain connection

Outdoor Unit: CH3632 Drain connection for left side

WARRANTY Refrigerant liquid line (3/8") Flare connection

SANYO FISHER COMPANY Refrigerant gas line (3/4") Flare connection

A Division of SANYO North America Corporation Hole for rear side refrigerant tubing

Manual background Hole for through-the-wall refrigerant tubing (ø3-15/16" hole)

Manual background Hole for fresh air intake (Knockout hole)

Manual background Hole for right side refrigerant tubing (Knockout hole)

Manual background Hole for left side drain connection (Knockout hole)

Manual background Hole for power supply (Conduit size 1/2")

Manual background Infrared rays receiver for wireless remote controller Manual background Cutting position for fresh air intake

6-3/32

7-31/32

12-7/32

-73/4 15/16-5

31/32-1

11-1/32

 

 

3-3/8

-15/16

 

11-1/32

4-3/4

 

3

 

Holes in the rear side (View from front)

6-5/16

pitch)

 

 

 

 

 

 

19/32-

bolthole

 

 

 

 

 

 

 

5-3/16

 

 

12

(Suspension

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

59-1/4(Suspension bolt hole pitch)

 

 

 

61-7/32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-1/2 7-1/4 7-3/4

3-5/32

11/16-6

5-3/4

5-9/16

 

1-3/32

Hole for wall-through piping (View from front)

 

6-5/16

 

2-25/32

 

1-3/8

26-3/8

9-7/8

Air intake

Outdoor Unit: CH3632

2 ft. or more

10

Air outlet or more

(Service space)

3-1/2

 

10

 

 

9-7/16

 

 

-1/2

-3/4

62

or more

8-7/16

 

 

 

5

7

Front

(Service space)

9-7/8

 

 

 

 

• Remote controller (Accessory)

 

 

 

6-25/32

 

 

4-1/16

 

 

 

 

5-25/32

2-13/32

 

23/32

6-11/16

26

4-21/64

 

 

1-31/32

1-31/32

13/32

 

 

 

13/16-

 

13-3/8

 

 

14-31/32

15-3/4

37

48-5/8

22-27/32

23-29/32

7-7/32

Dimension : inch

Manual background Hole for anchor bolt (4-ø13)

Manual background Refrigerant tube joint (narrow tube) Flare connection 3/8 in (9.52 mm)

Manual background Refrigerant tube joint (wide tube) Flare connection 3/4 in (19.05 mm)

Manual background Refrigerant tubing inlet Manual background Power supply inlet

WARRANTY

SANYO products are warranted against defects in materials and workmanship for the period below;

 

LABOR

PARTS

Compressor

30 Days

5

Years

Other Components

N/A

1

Year

Full specific warranty rights, conditions, exclusions and obligations are specified in the warranty packed with each products.

Because of a policy of continuous product improvements, SANYO reserves the right to change specifications and design without notice.

SANYO FISHER COMPANY

A Division of SANYO North America Corporation

21605 Plummer St. Chatsworth, CA 91311 Phone : (818) 998- 7322

Fax : (818) 701- 4160

Website: http://www.sanyohvac.com

Page 1
Image 1
Sanyo warranty Dimensional Data, Indoor Unit THS3632, Outdoor Unit CH3632, Warranty, Sanyo Fisher Company