3.7Joining Instructions

3.7.1Applying gasket (for connecting cases or installing side panels).

Make sure that all SANYO Cases are resting level.

Make sure that all required parts for joining are present (gasket, bolts, joint covers, nuts, etc.).

Remove all Rear Interior Panels, Wire Racks, Deck Pans, and Front Air Grilles from the far right and left ends of each case being joined.

Thoroughly clean all surfaces where the gasket will be placed to remove anything that might affect adhesion.

Place gasket along the areas shown in bold in the drawing at bottom. When connecting two cases, apply gasket to one case only.

CAUTION!

Perimeter gasket is required by NSF.

Do not stretch or twist gasket when applying.

Do not leave gaps. Always overlap gasket rather than leaving gaps.

Gasket ends that are open must be sealed off by applying silicone at the installation site.

Insufficient or improper sealing may lead to insufficient cooling and condensation.

Gasket

Important for

Preventing Condensation

11

Page 11
Image 11
Sanyo CVW-EXA124, CVW-EXA284, CVW-EXA184, CVW-EXA224 Joining Instructions,  Perimeter gasket is required by NSF