AUTOMATIC TEMPERATUER RECORDER
IAutomatic temperature recorder (optional)
To record the chamber temperature, an optional automatic temperature recorder is available. Please consult with our sales department or agency for recorder installation.
The available recorder model is
. 1Installation of temperature recorder
Following shows the procedure for installing a temperature recorder to the unit
(j)Take out a recorder from the package. Make sure to keep the instruction manual and warranty card in an accessible place.
@ Remove the mounting panel by opening and lifting it up.
®Wire the harness provided with the recorder properly as shown in the figure.
@Remove the cover from the mounting panel.
®Fix the recorder to the mounting panel with two screws.
®Install the mounting panel.
r:J) Route the recorder sensor into the chamber by passing through the monitoring hole on the back side.
@After installation, power on the unit. Check that the temperature alarm is operated properly when the temperature indicator needle (yellow) is matched to the upper limit temperature alarm needle (red).
Setting of iemperature alarm needle
Open the cover and set the upper limit temperature alarm needle (red) and lower limit temperature alarm needle (blue) manually to the required temperature on the scale. Both the upper and lower alarm needles should be set at least 3°C apart from the set temperature of the thermostat.
Upper limit temperature =set tem perature of the thermostat plus more than 3°C
Lower limit temperature = set temperature of the thermostat minus more than 3°C