Data Acquisition System
Features
• |
temperature, CO2 and O2 concentration, |
and operating condition can be |
integratedly monitored with one LAN- |
• Setting the upper/lower limits will cause |
you to be informed of an abnormality by |
you will also be informed when the |
Specifications
ModelMTR-L03
Product name Ethernet (LAN) Interface
Exterior
74 x 63 x 58mm
dimensions
connected personal computer. |
system recovers from the abnormality. |
(W x D x H)
(2.9” x 2.5” x 2.3”)
Items that can be monitored depend on the connected devices.
•Operating records are stored in sequence in the PC. It is unnecessary to fill in paper records or to enter in a record book. It is easy to convert the data into a graph.
Please note that there is a case in which data must be recorded on a paper.
•Devices can be set up remotely from a distant point, which saves entering a clean room.
When the operating setting can be changed through the network, it is impossible to change the operation setting on the panel of each device.
In addition, the system can be set so |
that the device conditions will be |
informed at a designated time whether |
or not there is an abnormality. |
A mail account which can be connected to an
•
For example, energy saving can be expected by changing to different setting temperatures for day and night operations.
•System access is protected by ID/Password.
Power supply DC5V (to be supplied from the attachment device)
Output terminal
Compatible | TCP/IP *Only static IP |
protocol | (Impossible to use DHCP.) |
|
|
Note | |
| sensors for temperature, etc. As |
| information such as |
| temperature, etc., results |
| measured at the sensors of the |
| incubators and freezers are |
| transmitted to the network. |
ModelMTR-5000
Product name SANYO Data acquisition software
No. of devices to 32 devices at most (up to 100 ch) be monitored
Devices to be SANYO biomedical devices
monitored connected to
Main functions
Monitoring PC CPU: Core2DUO or higher
Recommendable Memory: 1GB or more
specifications HDD: 80 GB or more
OS: Microsoft Windows XP SP3 (compatible with Windows Vista)
•SANYO cannot guarantee operations of all PCs satisfying the above recommendable specifications.
•If other software is installed in a PC in which this software was installed, information may be deleted due to malfunction.
Caution: SANYO guarantees the product under certain warranty conditions. SANYO in no way shall be responsible for any loss of content or damage to content.
•Appearance and specifications are subject to change without notice.
Map Display
Conditions of biomedical devices can be displayed on the map intelligibly. (A device showing a warning is displayed in red.)
Graph Display
Condition change of a selected channel can be displayed on a graph.
Channel List
The condition of each channel (measurement item) is displayed together with the upper and lower limit setting data.
Set Value Information
Set values of SANYO biomedical devices can be changed through the network.
*The above function is only applicable to remote- controllable devices.
Dimensions MTR-L03
[Unit : mm (inch)]
65 (2.6”)
74 (2.9”) | 63 (2.5”) |
58 (2.3”) | 28 (1.1”) |
Note:
All screen images shown in the catalog are composite images. In the unlikely event of a mechanical failure, the contents of the incubator and any recorded data cannot be guaranteed.
SANYO Electric Co., Ltd., Biomedical Division, Gunma is certified for:
Quality management system: ISO9001 / Medical devices quality management system: ISO13485 / Environmental management system: ISO14001
Distributed by:
SANYO Electric Co., Ltd.
Biomedical Division
http://biomedical.sanyo.com/
©2009 SANYO Printed in Japan 2009.7 MA
SHR147