25
For tubing, choose either the left side or right
side direction.
1. When routing the piping and wiring from the
left or right side of indoor unit, cut off the
tailing from the chassis in necessary.
(As shown in Fig 20)
Cut off the tailings 1 when routing the
wiring only.
Cut of the tailings 1 and tailings 2 when
routing both the wiring and piping.
2. Take out the piping from body case, wrap
the piping, electric wire, water pipe with
tape and push them through the piping hole.
(As show in Fig.21)
3. Hang the mounting slots of the indoor unit
on the upper tabs of the rear panel and
check if it is securely seated on the rear
panel. (As show in Fig.22)
4. Carefully bend the tubing (if necesasry) to
run along the wall in the direction of outdoor
unit and then tape as far as the fittings.
(Refer 9.3 on Pg. 22). The drain hose should
come staright down the wall to a point where
water run off won't stain the wall.
5. Connect the refrigerant tubing to the outdoor
unit. (After performing a leak test on the
connecting part, insulate it with the tubing
insulation. (Fig.21) Also, refer to Pg 28,
(connecting tubing between indoor and
outdoor unit).
Indoor unit

Floor level

Wall
Minimum height
from floor level
2.5m
Fig.23

9.5 How to Install the Indoor Unit

Fig.20
Tailing 2
Tailing 1
Fig.21
Gas side piping
External connection
electric wire
Liquid side piping
Gas side piping
insulation
Finally wrap
it with tape Water drainage
pipe
Liquid side piping
insulation
右后
Right
Right rear
Left rear
Left
Mounting board
Fixing hook
Mounting
board
Risk of Electric Shock
Do not supply power to
unit or operate it until
all tubing and wiring to
the outside unit are
completed.
CAUTION
For stable operation of the air
conditioner, do not install wall-
mounted type indoor units less than
2.5m from the floor level. (Fig.23)
NOTE
Fig. 22
9. INSTALL INDOOR UNIT
Installation Service