7. NOTICES FOR INSTALLATION

1. The unit installation work must be done by qualified
personnel according to the local rules and this manual.
2. Before install, please contact with local authorized
maintenance center. If the unit is not installed by the
authorized maintenance center, the malfunction may
not solved, due to discommodious contacts.
3. When removing the unit to the other place, please
firstly contact with the authorized SANYO Maintenance
Center in the local area.
Install in the following place may cause malfunction. If it
is unavoidable contact with service center please:
1. Place where strong heat sources, vapors, flammable gas or
volatile object are emitted.
2. Place where high-frequency waves are generated by radio
equipment, welders and medical equipment.
3. Place where a lot of salinities such as coast exists.
4. Place where a sulfured gas such as the hot spring zones is
generate.
5. Place where the oil (machine oil) is contained in the air.
6. Other place with special circumstance.
1. The air inlet and outlet vent should be far from the
obstruction, make sure that the air can be blown through
the whole room.
2. Select a position where the condensing water can be easily
drained out, and the places easily connected for outdoor
unit.
3. Select a location where the children can not reach.
4. Can select the place where is strong enough to withstand
the full weight and vibration of the unit. And will not increase
the noise.
5. Be sure to leave enough space to allow access for routine
maintenance. The height of installed location should be
200cm or more from the floor.6. Select a place about 1m or
more away from TVset or any other electric appliances.
7. Select a place where the filter can be easily taken out.
8. Make sure that the indoor unit installation should accord
with installation dimension diagram requirements. (Pg.24)

1. Select a location from which noise and outflow air emitted

by unit will not inconvenience neighbours, animals, plants.

2. Select a location with sufficient ventilation.

3. Select a location where there should be no obstructions

cover the inlet and outlet vent.

4. The location should be able to withstand the full weight and

vibration of the outdoor unit and permit safe installation.

5. Select a dry place, but do not expose under the direct

sunlight or strong wind.

7.1 Basic Requirements

for Installation

Position

7.2 Indoor Unit

Installation Position

Selection

7.3 Outdoor Unit

Installation

Position Selection

Important Notices
Installation Service