42
K
Tubing can be extended in 4 directions as shown in
Fig. 3-54.
Arrangement for Left Tubing
(a) Cut out the left tubing outlet. (Fig. 3-55)
Arrangement for Right Tubing
(a) Cut out the right tubing outlet using a hacksaw.
(Fig. 3-56)
Arrangement for Left-rear and Right-rear Tubing
(a) It is not necessary to cut a hole.
3-15. Wiring Instructions
General Precautions on Wiring
(1) Before wiring, confirm the rated voltage of the
unit as shown on its nameplate, then carry out
the wiring closely following the wiring diagram.
(2) Provide a power outlet to be used exclusively for
each unit. A power supply disconnect and circuit
breaker for overcurrent protection should be
provided in the exclusive line.
(3) To prevent possible hazards from insulation
failure, the unit must be grounded.
(4) All wiring must be connected tightly.
(5) Do not allow wiring to touch refrigerant tubing,
compressor, or any moving parts of the fan.
KHH(S)2672R
Left-rear
tubing
Left
tubing Right-rear
tubing
(Recommended)
Right tubing
Fig. 3-54
Fig. 3-55 Fig. 3-56
Unauthorized changes in the
internal wiring can be very
dangerous. The manufacturer
will accept no responsibility for
any damage or misoperation
that occurs as a result of such
unauthorized changes.
Right tubing
outlet
Left tubing
outlet
07-115 SSHP_II 5/7/07 4:00 PM Page 42