PARTS NAMES AND FUNCTIONS

6 Camera mounting screw hole (1/4"–20 UNC)

When mounting the camera to the mounting bracket, use this installation hole.

7 Lens cover fixing screw

8 GND (ground) terminal screw

Loosen the GND terminal screw, insert the coaxial cable into the clamp and tighten the GND terminal screw.

9 VIDEO OUT terminal screw

Align the centre wire of the coaxial cable with the VIDEO OUT terminal, then first tighten the cable clamp and then the VIDEO OUT terminal screw.

Cable type RG-6U (5C-2V)

The view angle of this camera is as follows: Horizontal: 71˚

Vertical: 53˚

Diagonal: 90˚

To adjust the camera angle, use the camera mounting bracket (sold separately).

F Line phase volume

When using a camera switcher to connect 2 cameras or more to one monitor, there may be a vertical roll of the images when switched. In such a case, set as described below.

Switch the display on the monitor from camera 1 to camera 2.

Adjust the LINE PHASE volume on camera 2 until the vertical roll of the image stops.

If more than two cameras are used, please repeat this procedure for all the cameras.

CAUTION:

If the vertical roll cannot be corrected by setting the LINE PHASE volume on camera 2, try setting the LINE PHASE volume on camera

1.If it still cannot be corrected, please check that the polarity of the power cords of all connected devices is correct.

English 5