Control/Address Settings
When you connect the camera to a controller, it is necessary to configure the interface board control switch and address switch.
This is used to configure transmission rate and protocol, etc.
¥Switches 4 and 5 are not used.
¥Settings in bold typeface in the table below show the factory default configurations.
❶Baud RateON
1 2 3 4 5 6
Configure the transmission rate of connected devices to the transmission | ❶ ❷ | ❸ | |||
rate of the camera. |
|
|
| ||
|
|
|
|
| |
|
|
|
|
|
|
Transmission Rate | Switch 1 | Switch 2 |
|
|
|
2400 | OFF | OFF |
|
|
|
4800 | ON | OFF |
|
|
|
9600 | OFF | ON |
|
|
|
19200 | ON | ON |
|
|
|
When protocol is set to “PELCO”, set to 2400.
❷ProtocolSelect the protocol for controlling the camera.
Protocol | Switch 3 | Corresponding Protocol |
SSP (SANYO) | OFF | Automatic switching between Sanyo SSP and high speed SSP |
PELCO | ON | Automatic switching between |
When you connect multiple cameras, set the terminator setting (Switch 6) of the final device to ÒONÓ and all other devices to ÒOFFÓ.
■Address switchWhen you connect multiple cameras, allocate a unique RS485 protocol address (camera number) to each camera.
Configure the address by setting the dip switches to ÒONÓ and ÒOFFÓ.
For further information, refer to the ÒAddress Settings TableÓ on the next page.
ON
1 2 3 4 5 6 7 8
9