VIEW SETTING

English

Backlight compensation additional settings 1

Multi-spot evaluative metering (MULT)

1

IRIS SETTING

2

BLC SETTING

 

 

BLC

 

MULT ‚

(BLC WEIGHT)

 

 

SENSE UP

OFF

í

------ú------

ü

7

 

(LEVEL)

 

 

(BRIGHT)

 

 

 

 

 

í

------ú------

ü

7

í

-----ú+------

ü

40

 

 

 

1Use the cursor button (j or l) to move the cursor to BLC, then use the cursor button (d or c) to select a backlight compensation method. (Ex: MULT) Then press the SET button.

The BLC SETTING screen will appear.

Available settings:

MULT (Multi-spot evaluative metering): Evaluates the entire screen and corrects according to the best image obtained.

CENT (5 spot centerweighted average metering): Measures light mainly at the center and corrects according to the best image obtained. (See p26)

MASK (48 multi-spot metering): Covers bright areas such as persons with mask patterns and treats light measurement output as irrelevant. (See p28)

2Use the cursor button (d or c) to select the value of

BLC WEIGHT. (Sets backlight and brightness level.) Available settings: 0 – 15

Note: The larger the number, the more backlighting works.

3Use the cursor button (j or l) to move the cursor to BRIGHT, and then use the cursor button (d or c) to select the compensation level.

Available settings: 0 – 15

Note: When the number becomes larger, it brightens, and the compensation level can be set for the brightness of the backlighting.

To close the menu screen or return to the previous screen, select BACK or END for MENU and press the SET button.

Note: When using multi-spot evaluative metering, the background behind the target object will become very dark. If a target image in the center of the image is too bright while using the multi-spot evaluative metering mode, switch to the 5 spot centerweighted average metering mode.

25