STATUS: Two-color (Red, Green) LED that indicates the
following status conditions:
Green - Illuminated when printer is ready to receive
data. It is turned on and off by toggling the LINE
key.
Red -Illuminated when there is a system fault such
as an open print head.
LINE: Momentary switch. Pressing this key toggles the printer
between the on-line and off-line mode. When the
printer is on-line, it is ready to receive data from the
host. This key acts as a pause during a print job by
taking the printer off-line. It can also be used as a
Pause function key to stop label during the printing
process.
FEED: Momentary switch. Pressing this key feeds one blank
label through the printer when it is off-line. When the
printer is on-line, another copy of the last label will be
printed (can be disabled via the LCD panel).
DSW2-3: Located behind the Front Access Door. DIP switch
array to set operational parameters of the printer.
DSW1 is used to set the RS232 parameters and is
located on the RS232 interface board.
LCD: 2 Line x 16 Character LCD display. Used for setting
operational parameters of the printer.
LABEL TAKEN
THRESHOLD:
Located behind the Front Access Door. This
potentiometer is used to adjust the sensing level of the
Label Taken Sensor. Active only when the Label
Dispense option is installed.
OPTION CONNECTOR: Located behind the Front Access Door. This connector
is used for the cutter and dispenser optional
accessories.
LABEL TAKEN: Located behind the Front Access Door. This LED is
illuminated when a label is not present in the Label
Taken Sensor. If it is not illuminated, a label has been
detected in the sensor and printing will be inhibited until
it is removed. This LED is active only when the Label
Dispense option is installed. It is used to adjust the
Label Taken Sensor threshold.
SATO CL Series āeā Printers PN 9001074 Rev. B Page 2-15
Section 2. Installation