Schneider Electric MNA01M001EN manual Mains reactor and external mains filter

Models: MNA01M001EN

1 64
Download 64 pages 2.13 Kb
Page 39
Image 39

LXM32

3 Engineering

3.8Mains reactor and external mains filter

If a mains reactor and an external mains filter are required, the mains reactor and external mains filter must be arranged according to the following illustrations for EMC reasons.

L1

 

 

 

 

 

L2

 

 

 

 

 

L3

 

 

 

 

 

E1

S1

L1

L1'

 

 

E2

S2

L2

L2'

 

 

E3

S3

L3

L3'

 

 

 

 

 

L3 L2 L1

L3 L2 L1

L3 L2 L1

 

 

 

PC/- PA/+

PC/- PA/+

PC/- PA/+

DC+

 

 

 

 

 

DC -

 

 

 

 

 

Figure 13: Wiring of drives with common mains fuse, mains reactor and mains filter, example shows three-phase drives.

MNA01M001EN, V1.01, 08.2014

Common DC bus

39

Page 39
Image 39
Schneider Electric MNA01M001EN manual Mains reactor and external mains filter