PROBLEM

POSSIBLE CAUSE

SOLUTION/REASONS

Ammeter reads less than

Extension cord too long or

Use shorter or heavier

selected charge rate when

wire gauge too small.

gauge extension cord.

charging a discharged

Weak cell or sulfated plate

Sulfated battery will

battery.

 

in battery.

eventually take a normal

 

 

charge if left connected. If

 

 

the battery will not take a

 

 

charge, have it tested by a

 

 

Sears technician.

 

Battery is only partially

Continue charging battery.

 

discharged.

 

Charger makes a loud

Transformer laminations

Continue charging. Buzz

buzz or hum.

vibrate (buzz).

is not abnormal.

 

Shorted diode (hum).

Have charger tested by

 

 

Sears technician.

Ammeter reading stays

Battery is severely dis-

Continue charging battery

high.

charged.

for two more hours. If

 

 

problem continues, have

 

 

the battery checked by a

 

 

Sears or other qualified

 

 

service dealer.

 

 

 

17