18.before returning for repair

Please do not return for repair before speaking to a customer service representative (1-800-621-5485).

18.1When a charging problem arises, make certain that the battery is capable of accepting a normal charge. Use a good battery to double check all con- nections, AC outlet for a full 120-volts, charger clamps for correct polarity, and the quality of the connections from the cables to the output connector and from the output connector to the battery system. The output connec- tors must be clean.

18.2When a battery is very cold, partially charged or sulfated, it will not draw the full rated amperes from the charger. It is dangerous and damaging to a battery to force higher amperage into it than it can effectively use in recharging.

18.3When an unknown operating problem arises, please read the complete manual and call the customer service number for information. Doing so will usually eliminate the need for return.

19.technical specifications

This charger is intended for use with lead-acid and gel-cell batteries only.

 

Electrical

Nominal Operating Voltage (VAC)

 

100 – 240

Input Voltage Range (VAC)

 

85 – 264

Input Current (A rsm max)

 

2.9 @ 85V 60Hz

Output Power (W)

 

120 nom. 130 max.

Output Current (A max)

 

5.0

Output Voltage (VDC nom./

 

24 / 2 – 29.5

range)

 

 

 

 

Mechanical

Case

 

Black Anodized Aluminum

Dimensions (inches)

 

7 L x 5½ W x 2 H

Weight

 

1.80 lbs

 

 

Connections

AC Power Input

 

IEC 320/C14 Male on Cable

DC Power Output Adapters

 

Option #1 – Battery Clamp Output Cord

 

 

Option #2 – 3-Pin XLR 3-12C Output Cord

 

 

Option #3 – 3/8” Dia. Ring Terminal Output

 

 

Cord