Do not install a fuse with a higher amp rating than the original fuse, as this may damage the inverter and any product you use with the inverter. Make sure to correct the cause of the blown fuse before using the inverter again.

9.TROUBLESHOOTING

PROBLEM

REASON

SOLUTION

Red LED is on,

Poor contact at

Unplug and reinsert

audible alarm

terminals.

the 12V plug or check

is on, and/or

 

connections at power

inverter does not

 

supply.

function.

Fuse blown.

See “IF THE INVERTER

 

 

 

FUSE BLOWS” section.

 

Inverter shutdown.

See “LED INDICATOR

 

 

AND SHUTDOWN

 

 

PROTECTION” section.

 

Inverter may not be

See Warranty and call

 

working properly.

Customer Service.

The red LED is

12V Accessory

Check for poor connection

lit and the green

plug or clips are

to battery and frame.

LED is not.

not making a good

Make sure connection

 

connection to the

points are clean. Rock

 

battery.

clips back and forth for a

 

 

better connection.

 

Connections are

Unplug the charger and

 

reversed.

reverse the clips.

 

Inverter may not be

See Warranty and call

 

working properly.

Customer Service.

 

 

 

• 9 •

Page 9
Image 9
Schumacher PI-200 owner manual Troubleshooting Problem Reason Solution, Shutdown