11.MOVING AND STORAGE INSTRUCTIONS

11.1Store the charger unplugged, in an upright position. The cord will still conduct electricity until it is unplugged from the outlet.

11.2If the charger is moved around the shop or transported to another location, take care to avoid/prevent damage to the cords, clips and charger. Failure to do so could result in personal injury or property damage.

12.SPECIFICATIONS

Input

230V~50Hz

.86A

 

 

 

– Slow

 

 

 

– Medium

1.15A

 

 

 

– Fast

2.85A

 

 

 

– Engine Start

8.5A

 

 

 

Output

 

 

 

 

 

– Slow

6/12V

 

 

3A

 

 

– Medium

6/12V

 

 

5A

 

 

– Fast

6/12V

 

 

20A 105 seconds on / 5A 180 seconds on

 

 

– Engine Start

12V

 

90A Peak 150A @ 0V

 

Weight

12.8 lbs. (5.82 kg)

Reverse Polarity Protection

Yes

 

 

 

13.TROUBLESHOOTING AND ERROR CODES Error Codes

ERROR

DESCRIPTION

CAUSE

CODE

 

 

 

The battery voltage is still under

Could be caused by trying to charge a 6 volt

F01

10V (for a 12V battery) or 5V

battery on the 12 volt setting, or the battery

(for a 6V battery) after 2 hours of

could be bad; have it checked or replaced.

 

 

charging.

 

F02

The charger cannot desulfate

The battery could not be desulfated; have it

the battery.

checked or replaced.

 

 

The battery was unable to reach

Could be caused by trying to charge a large

 

the “full charged” voltage.

battery or bank of batteries on too low of a

F03

 

current setting, or the battery may have a

 

shorted cell. Try again with a higher current

 

 

 

 

setting, or have the battery checked or

 

 

replaced.

F04

The connections to the battery

The battery is connected backwards. Unplug

are reversed.

the charger and reverse the connections to

 

 

the battery.

 

The charger was unable to

The battery won’t hold a charge. Could be

 

keep the battery fully charged in

caused by a drain on the battery, or the

F05

maintain mode.

battery could be bad. Make sure there are

 

no loads on the battery. If there are, remove

 

 

 

 

them. If there are none, have the battery

 

 

checked or replaced.

 

The charger detected that the

The charger automatically shuts the current

F06

battery may be getting too hot

off if it detects the battery may be getting too

(thermal runaway).

hot or the battery may have a shorted cell.

 

 

 

Have the battery checked or replaced.

If you get an error code, check the connections and settings and/or replace the battery.