PROBLEM

REASON

SOLUTION

 

 

 

Inverter does not

Poor contact at

Check for poor

turn on.

terminals

connection to battery

 

 

or power supply.

 

 

Make sure connection

 

 

points are clean. Rock

 

 

clamps back and forth

 

 

for a better connection.

 

Fuse is blown.

A blown fuse is

 

 

usually caused by

 

 

reverse polarity or

 

 

a short circuit within

 

 

the inverter.

 

 

To replace, contact

 

 

a qualified service

 

 

technician who will

 

 

diagnose the inverter

 

 

and replace the fuse(s)

 

 

with the appropriate

 

 

replacement(s).

 

Inverter may be

See warranty and call

 

defective.

Customer Service

 

 

1-800-621-5485

 

 

(Hours 7:00 am to

 

 

5:00 pm CST).

9. SPECIFICATIONS

 

 

 

Model: XI41DU

 

410 Watts

Maximum Continuous Output.

.........................................

Surge Capacity (0.1 second)

820 Watts

Optimum Efficiency

85%

No Load Current Draw

<0.5A

Output Frequency

60Hz ± 3Hz

Output Wave Form

Modified Sine Wave

Input Voltage Range

10.5V – 15.5V

DC

Low Battery Alarm

Audible, 11V

± 0.3V

DC

Low Voltage Shutdown

Under 10.5V

± 0.3V

DC

High Voltage Shutdown

Over 15.5V

± 0.5V

DC

• 10 •

Page 11
Image 11
Schumacher owner manual Specifications, Model XI41DU