amperage when not in use, it should be unplugged to avoid battery drain.

6.LED DISPLAY

The LED display identifies the current status of the inverter.

VOLTS IN : The voltage of the vehicle’s battery, Portable Power jump starter or DC power source.

VOLTS OUT : The voltage supplied to the device through the AC receptacle.

WATTAGE OUT : The power or wattage supplied to the device plugged into the inverter.

An audio alarm will sound when any of the following codes display. To stop the alarm, press the ON/OFF switch:

 – The inverter is not functional. See warranty and call Customer Service 1-800-621-5485 (Hours: 7:00 am to 5:00 pm CST).

 – The vehicle’s battery voltage is more than 15.5-volts. The inverter will automatically restart after the voltage drops below 15.0-volts.

 – The continuous load demand from the device exceeds the inverter’s wattage output.

 – The inverter is overheated and automatically turns off for a period of 1 to 3 minutes to cool. Make sure the inverter is well ventilated. It will automatically restart after it cools.

 – The vehicle’s battery voltage is less than 10.5-volts.

 – Short circuit, power surge or overload in the device.

7.IF THE INVERTER FUSE BLOWS

Your power inverter is fitted with a fuse, which should not have to be replaced under normal operating conditions. A blown fuse is usually caused by reverse polarity or a short circuit within the device or equipment being operated.If the fuse does blow:

1.Disconnect the device or equipment immediately.

2.Find the source of the problem, and repair it.

3.Install a new fuse, 15-amp. The fuse can be found on the end of the plug on the inverter.

4.Do not tighten the fuse cap too tight; finger tight is sufficient.

• 7 •

Page 8
Image 8
Schumacher XI41DU owner manual LED Display, If the Inverter Fuse Blows