GENERAL MAINTENANCE CONTINUED

UNPLUG THE UNIT BEFORE PERFORMING ANY MAINTENANCE PROCEDURES

CHANGING THE UV LAMP

1.Unplug the power to the unit.

2.Remove the Primary filter by removing the 4 corner screws.

3.Remove the tape on either end of the UV Lamp if it is present.

4.Place one finger from each hand (middle or index) on the metal ends of the UV Lamp. Very carefully, apply just enough pressure to roll the lamp (preferably towards the back of the unit) until it is loose. Note: Be careful not to cut yourself when removing the UV lamp.

5.Remove the old UV Lamp and insert the new one by aligning the end pins to slide into the end sockets (just like a standard fluorescent bulb).

6.Once both sets of end pins are in their slots, place one finger from each hand (middle or index) on the metal ends of the UV Lamp. Very carefully apply just enough pressure to roll the lamp (preferably towards the back of the unit) until it is secure on both ends. Note: Be careful not to cut yourself when reinstalling the UV lamp.

7.Place the Primary filter back in its original position and re-install the four corner screws.

8.Plug the power cord back into the unit and turn it on. Confirm the new UV Lamp is functioning properly. If it is not working properly, repeat steps 1, 2, and 6. Test the UV Lamp again.

7