CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 14
5.0 RELIABILITY SPECIFICATIONS
The following reliability specifications assume correct host and drive operational interface, including all interface timings,
power supply voltages, environmental requirements and drive mounting constraints.
5.1 ERROR RATES
The error rates stated in this manual assume the following:
• The drive is operated in accordance with this manual using DC power as defined in paragraph 6.2, "DC power require-
ments."
• Errors caused by host system failures are excluded from error rate computations.
• Assume random data.
• Default OEM error recovery settings are applied. This includes AWRE, ARRE, full read retries, full write retries and full retry
time.
• Error rate specified with automatic retries and data correction with ECC enabled and all flaws reallocated.
5.1.1 Recoverable Errors
Recovereable errors are those detected and corrected by the drive, and do not require user intervention.
Recoverable Data errors use retries and correction. Application of ECC on-the-fly correction alone is not considered a
Recovered Data error.
Recovered Data error rate is determined using read bits transferred for recoverable errors occurring during a read, and using
write bits transferred for recoverable errors occurring during a write.
5.1.2 Unrecoverable Errors
Unrecoverable Data Errors (Sense Key = 03h) are specified at less than 1 sector in error per 1016 bits transferred.
Unrecoverable Data Errors resulting from the same cause are treated as 1 error for that block.
5.1.3 Seek errors
A seek error is defined as a failure of the drive to position the heads to the addressed track. After detecting an initial seek
error, the drive automatically performs an error recovery process. If the error recovery process fails, a seek positioning error
(Error code = 15h or 02h) will be reported with a Hardware error (04h) in the Sense Key. Recoverable seek errors are
specified at Less than 10 errors in 108 seeks. Unrecoverable seek errors (Sense Key = 04h) are classified as drive failures.
5.1.4 Interface errors
An interface error is defined as a failure of the receiver on a port to recover the data as transmitted by the device port
connected to the receiver. The error may be detected as a running disparity error, illegal code, loss of word sync, or CRC
error. The total error rate for a loop of devices is the sum of the individual device error rates.
Seek error rate: Less than 10 errors in 108 seeks
Read Error Rates
Recovered Data Less than 10 errors in 1012 bits transferred (OEM default settings)
Unrecovered Data Less than 1 sector in 1016 bits transferred
Miscorrected Data Less than 1 sector in 1021 bits transferred
Interface error rate: Less than 1 error in 1012 bits transferred with minimum receive eye.
Less than 1 error in 1014 bits transferred with typical receive eye.
See Section 11.6.4, "FC Differential input." on page 65
Annualized Failure Rate (AFR): 0.55%
Preventive maintenance: None required