2.9Environmental specifications

2.9.1Ambient temperature

Ambient temperature is defined as the temperature of the environment immediately surrounding the drive. Actual drive case temperature should not exceed 69°C (156°F) within the operating ambient conditions for standard models, or 64°C (147°F) within the operating ambient conditions for all models. Recommended mea- surement locations are shown in See Figure 6 on page 25.

Above 1,000 feet (305 meters), the maximum temperature is derated linearly to 112°F (44°C) at 10,000 feet (3,048 meters).

Operating:

0° to 60°C (32° to 140°F)

 

 

Nonoperating:

–40° to 70°C (–40° to 158°F)

 

 

2.9.2Temperature gradient

Operating:

20°C per hour (68°F per hour max), without condensation

 

 

Nonoperating:

30°C per hour (86°F per hour max)

 

 

2.9.3Humidity

2.9.3.1Relative humidity

Operating:

5% to 90% noncondensing (30% per hour max)

 

 

Nonoperating:

5% to 95% noncondensing (30% per hour max)

 

 

2.9.3.2Wet bulb temperature

Operating:

37.7°C (99.9°F max)

 

 

Nonoperating:

40°C (104°F max)

 

 

2.9.4Altitude

Operating:

–60.96 m to 3,048 m (–200 ft. to 10,000+ ft.)

 

 

Nonoperating:

–60.96 m to 12,192 m (–200 ft. to 40,000+ ft.)

 

 

Barracuda 7200.8 PATA Product Manual, Rev. F

15

Page 21
Image 21
Seagate ST3250623A, 7200.8 PATA, ST3300631A, ST3400632A manual Environmental specifications