12 U10 Family Product Manual , Rev. A
1.8.3 Humidity
1.8.3.1 Relative Humidity
1.8.3.2 Wet bulb temperature
1.8.4 Altitude
1.8.5 Shock
All shock specifications assume that the drive is mounted securely wit h
the input shock applied at the drive mounting screws. Shock may b e
applied in the X, Y or Z axis.
1.8.5.1 Operating shock
These drives comply with the performance levels speci fied in this docu-
ment when subjected to a maximum operating shock of 63 Gs (ba sed
on half-sine shock pulses of 2 msec). Shocks should not be repe ated
more than two times per second.
1.8.5.2 Nonoperating shock
The nonoperating shock level that the drive can e xperience without
incurring physical damage or degradation in p erformance when subse-
quently put into operation is 350 Gs (based on nonrepetitive half-sine
shock pulses of 2 msec duration).
1.8.6 Vibration
All vibration specifications assume that the drive is mounted secu rely
with the input vibration applied at the drive mounting screws. Vibration
may be applied in the X, Y or Z axis.
Operating 5% to 90% noncondensing (30% per hour max)
Nonoperating 5% to 95% noncondensing (30% per hour max)
Operating 29.4°C (84°F) max
Nonoperating 40.0°C (104°F) max
Operating –61 m to 3,048 m (–200 ft to 10,000+ ft)
Nonoperating –122 m to 12,192 m (–400 ft to 40,000+ ft)