8 U10 Family Product Manual, Rev. A
1.7.1 Power consumption
Power requirements for the drives are listed in the table on page 9.
Typical power measurements are based on an average of drives tested,
under nominal conditions, using 5.0V input voltage at 25°C ambient
temperature.
Spinup power
Spinup power is measured from the time of power-on to the time that
the drive spindle reaches operating speed.
Seek Mode
During seek mode, the read/write actuator arm moves toward a
specific position on the disc surface and does not execute a read or
write operation. Servo electronics are active. Seek mod e power rep-
resents the worst-case power consumption, using only random seeks
with read or write latency time. This mode is not typical and is provide d
for worst-case information.
Read/Write power and current
Read/write power is measured with the heads on track, based on a
16-sector write followed by a 32-msec delay, then a 16-sector read
followed by a 32-msec delay.
Operating power and current
Operating power is measured using 40 percent random seek s, 40
percent read/write mode (1 write for each 10 reads) and 20 percent
drive inactive.
Idle mode power
Idle mode power is measured with the drive up to spee d, with s ervo
electronics active and with the heads in a random track locati on.
Standby mode
During Standby mode, the drive accepts commands, but the driv e is
not spinning, and the servo and read/write electronic s are in p ower-
down mode.