2.7.5Shock
All shock specifications assume that the drive is mounted securely with the input shock applied at the drive mounting screws. Shock may be applied in the X, Y or Z axis.
2.7.5.1Operating shock
These drives comply with the performance levels specified in this document when subjected to a maximum operating shock of 63 Gs based on
2.7.5.2Nonoperating shock
The nonoperating shock level that the drive can experience without incurring physical damage or degradation in perfor- mance when subsequently put into operation is 300 Gs based on a nonrepetitive
2.7.6Vibration
All vibration specifications assume that the drive is mounted securely with the input vibration applied at the drive mounting screws. Vibration may be applied in the X, Y or Z axis.
2.7.6.1Operating vibration
The maximum vibration levels that the drive may experience while meeting the performance standards specified in this document are specified below.
5 to 350Hz | 0.50 Gs |
|
|
350 to 500Hz | 0.25 Gs |
|
|
2.7.6.2Nonoperating vibration
The maximum nonoperating vibration levels that the drive may experience without incurring physical damage or degrada- tion in performance when subsequently put into operation are specified below.
5 to 350Hz | 5.0 Gs |
|
|
350 to 500Hz | 2.0 Gs |
|
|
Barracuda XT Series SATA Product Manual, Rev. C | 11 |