2.11Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table:

Table 8:

Radio frequency environments

 

 

 

 

 

 

 

Test

 

Description

Performance level

Reference standard

 

 

 

 

 

Electrostatic

 

Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV

B

EN 61000-4-2: 95

discharge

 

 

 

 

Radiated RF

 

80 to 1,000 MHz, 3 V/m,

A

EN 61000-4-3: 96

immunity

 

80% AM with 1 kHz sine

 

ENV 50204: 95

 

 

900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz

 

 

Electrical fast

± 1 kV on AC mains, ± 0.5 kV on external I/O

B

EN 61000-4-4: 95

transient

 

 

 

 

Surge immunity

± 1 kV differential, ± 2 kV common, AC mains

B

EN 61000-4-5: 95

 

 

 

 

Conducted RF

150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz sine

A

EN 61000-4-6: 97

immunity

 

 

 

 

Voltage dips,

 

0% open, 5 seconds

C

EN 61000-4-11: 94

interrupts

 

0% short, 5 seconds

C

 

 

 

40%, 0.10 seconds

C

 

 

 

70%, 0.01 seconds

B

 

22

Barracuda ES Serial ATA Product Manual, Rev. D

Page 28
Image 28
Seagate ST3500830NS, ST3250820NS, ST3250620NS, ST3320620NS manual Electromagnetic immunity, Radio frequency environments