8.0Installation
Cheetah NS FC disc drive installation is a
Use the
If multiple devices are on the same
Loop initialization is the process used to verify or obtain an address. The loop initialization process is per- formed when power is applied to the drive, when a device is added or removed from the Fibre Channel loop, or when a device times out attempting to win arbitration.
•Set all option selections in the connector prior to applying power to the drive. If you change options after applying power to the drive, recycle the drive power to activate the new settings.
•It is not necessary to
8.1Drive ID/option selection
All drive options are made through the interface connector (J1). Table 21 provides the pin descriptions for the
8.2Drive orientation
The drive may be mounted in any orientation. All drive performance characterizations, however, have been done with the drive in horizontal (discs level) and vertical (drive on its side) orientations, which are the two pre- ferred mounting orientations.
8.3Cooling
The host enclosure must dissipate heat from the drive. You should confirm that the host enclosure is designed to ensure that the drive operates within the temperature measurement guidelines described in Section 6.4.1. In some cases, forced airflow may be required to keep temperatures at or below the temperatures specified in Section 6.4.1.
Cheetah NS FC Product Manual, Rev. B | 41 |