Table 4:

500GB drive (Standard & SED model) DC power requirements

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.0Gb mode

6.0Gb mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes

(Amps)

(Amps)

(Amps)

(Amps)

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

 

 

 

 

 

 

 

+5V

+12V [4]

+5V

+12V [4]

 

 

 

 

 

 

 

Regulation

 

[5]

±5%

±5% [2]

±5%

±5% [2]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[1] [7]

0.42

0.21

0.43

0.21

Avg idle current DCX

 

 

 

 

Advanced idle current

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Idle_A

 

 

0.41

0.21

0.43

0.21

 

 

 

 

 

 

 

 

 

Idle_B

 

 

0.23

0.19

0.24

0.19

 

 

 

 

 

 

 

 

 

Idle_C/ Standby_Y

 

 

0.23

0.12

0.24

0.12

 

 

 

 

 

 

 

 

 

Standby_Z

 

 

0.22

0.02

0.24

0.02

Maximum starting current

 

 

 

 

 

 

 

 

 

 

 

 

 

(peak DC) DC

3σ

[5]

0.55

1.88

0.56

1.89

 

(peak AC) AC

3σ

[5]

0.83

2.42

0.90

2.58

 

3σ

 

 

 

 

 

Delayed motor start (max) DC

[1] [6]

0.35

0.03

0.38

0.03

Peak operating current (random read):

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[1] [6]

0.55

0.42

0.57

0.42

 

Typical DCX

 

 

 

Maximum DC

3σ

[1]

0.57

0.44

0.59

0.44

 

Maximum (peak) DC

3σ

 

1.13

1.53

1.19

1.53

Peak operating current (random write)

 

 

 

 

 

 

 

 

 

 

 

 

0.61

0.34

0.62

0.34

 

Typical DCX

 

 

 

 

Maximum DC

3σ

 

0.63

0.35

0.64

0.35

 

Maximum (peak) DC

3σ

 

1.31

1.57

1.31

1.57

Peak operating current (sequential read)

 

 

 

 

 

 

 

 

 

 

 

 

0.96

0.23

0.98

0.23

 

Typical DCX

 

 

 

 

Maximum DC

3σ

 

0.98

0.24

1.01

0.24

 

Maximum (peak) DC

3σ

 

1.15

0.45

1.23

0.45

Peak operating current (sequential write)

 

 

 

 

 

 

 

 

 

 

 

 

1.05

0.23

1.06

0.23

 

Typical DCX

 

 

 

 

Maximum DC

3σ

 

1.07

0.24

1.08

0.24

 

Maximum (peak) DC

3σ

 

1.32

0.42

1.34

0.42

 

 

 

 

 

 

 

 

 

 

 

 

[1]Measured with average reading DC ammeter.

[2]Instantaneous +12V current peaks will exceed these values.

[3]Power supply at nominal voltage. N (number of drives tested) = 6, 35 Degrees C ambient.

[4]For +12 V, a –10% tolerance is allowed during initial spindle start but must return to ±5% before reaching 7200 RPM. The ±5% must be maintained after the drive signifies that its power-up sequence has been completed and that the drive is able to accept selection by the host initiator.

24

ConstellationES Series SAS Product Manual, Rev. D

Page 32
Image 32