ST3500414SS and ST3500415SS in 3Gb operation

Please refer to Table 2 for power dissipation numbers.

To obtain operating power for typical random read operations, refer to the following I/O rate curve (see Figure 8). Locate the typical I/O rate for a drive in your system on the horizontal axis and read the corresponding +5 volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by 3.4123.

 

 

 

ST3500414SS CURRENT/POWER vs THROUGHPUT (SAS - 3.0GB)

 

 

 

 

 

 

Random 8 Block Reads

 

 

 

 

1

 

 

 

 

 

 

 

 

10

5Volt A

 

0.9

 

 

 

 

 

 

 

 

9

12 Volt A

 

 

 

 

 

 

 

 

 

Watts

 

 

 

 

 

 

 

 

 

 

 

 

0.8

 

 

 

 

 

 

 

 

8

 

 

0.7

 

 

 

 

 

 

 

 

7

P

 

 

 

 

 

 

 

 

 

 

 

o

s

0.6

 

 

 

 

 

 

 

 

6

w

 

 

 

 

 

 

 

 

e

e

 

 

 

 

 

 

 

 

 

 

r

r

 

 

 

 

 

 

 

 

 

 

(

e

 

 

 

 

 

 

 

 

 

5

w

p 0.5

 

 

 

 

 

 

 

 

a

m

 

 

 

 

 

 

 

 

 

t

A0.4

 

 

 

 

 

 

 

 

4

t

 

 

 

 

 

 

 

 

s

 

 

 

 

 

 

 

 

 

 

 

)

 

0.3

 

 

 

 

 

 

 

 

3

 

 

0.2

 

 

 

 

 

 

 

 

2

 

 

0.1

 

 

 

 

 

 

 

 

1

 

 

0

 

 

 

 

 

 

 

 

0

 

 

0

20

40

60

80

100

120

140

160

180

 

I/Os per Second

Figure 8. ST3500414SS & ST3500415SS (3Gb) DC current and power vs. input/output operations per second

Note. For power details about SED vs. non-SED drive, please refer to section 7.8.

ConstellationES Series SAS Product Manual, Rev. D

33

Page 41
Image 41
Seagate ST35000415SS manual ST3500414SS and ST3500415SS in 3Gb operation, ST3500414SS CURRENT/POWER vs Throughput SAS 3.0GB