3.11Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table:
Table 4: | Radio frequency environments |
|
| |
|
|
|
|
|
Test |
| Description | Performance level | Reference standard |
|
|
|
|
|
Electrostatic |
| Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV | B | EN |
discharge |
|
|
|
|
Radiated RF |
| 80 to 1,000 MHz, 3 V/m, | A | EN |
immunity |
| 80% AM with 1 kHz sine |
| ENV 50204: 95 |
|
| 900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz |
|
|
Electrical fast | ± 1 kV on AC mains, ± 0.5 kV on external I/O | B | EN | |
transient |
|
|
|
|
Surge immunity | ± 1 kV differential, ± 2 kV common, AC mains | B | EN | |
|
|
|
| |
Conducted RF | 150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz sine | A | EN | |
immunity |
|
|
|
|
Voltage dips, |
| 0% open, 5 seconds | C | EN |
interrupts |
| 0% short, 5 seconds | C |
|
|
| 40%, 0.10 seconds | C |
|
|
| 70%, 0.01 seconds | B |
|
3.12Reliability
3.12.1Annualized Failure Rate (AFR) and Mean Time Between Failures (MTBF)
The product shall achieve an Annualized Failure Rate - AFR - of 0.62% (Mean Time Between Failures - MTBF
-of 1.4 Million hrs) when operated in an environment that ensures the HDA case temperatures do not exceed 40°C. Operation at case temperatures outside the specifications in Section 3.9 may increase the product Annu- alized Failure Rate (decrease MTBF). AFR and MTBF are population statistics that are not relevant to individ- ual units.
AFR and MTBF specifications are based on the following assumptions for business critical storage system environments:
•8760
•250 average motor start/stop cycles per year.
•Operations at nominal voltages.
•Systems will provide adequate cooling to ensure the case temperatures do not exceed 40°C. Temperatures outside the specifications in Section 3.8 will increase the product AFR and decrease MTBF.
Nonrecoverable read errors | 1 per 1015 bits read, max |
Annualized Failure Rate (AFR) | 0.62% (nominal power, 40°C case temperature) |
|
|
Load unload cycles | 300,000 cycles |
|
|
Warranty | To determine the warranty for a specific drive, use a web browser to access the fol- |
| lowing web page: |
| |
| From this page, click on the “Verify Your Warranty” link. You will be asked to provide |
| the drive serial number, model number (or part number) and country of purchase. |
| The system will display the warranty information for your drive. |
Preventive maintenance | None required. |
|
|
20 | Constellation.2 Serial ATA Product Manual, Rev. B |