3.10Environmental specifications
3.10.1Ambient temperature
Ambient temperature is defined as the temperature of the environment immediately surrounding the drive.
Above 1000 feet (305 meters), the maximum temperature is derated linearly by 1°C every 1000 feet.
Operating: | 0° to 60°C (32° to 140°F) |
|
|
Nonoperating: | |
|
|
3.10.2Temperature gradient
Operating | 20°C per hour (68°F per hour max), without condensation |
|
|
Nonoperating | 35°C per hour (95°F per hour max), without condensation |
|
|
3.10.3Humidity
3.10.3.1Relative humidity
Operating | 5% to 95% noncondensing (30% per hour max) |
|
|
Nonoperating | 5% to 95% noncondensing (30% per hour max) |
|
|
3.10.3.2Wet bulb temperature
Operating | 37.7°C (99.86°F max) |
|
|
Nonoperating | 40°C (104°F max) |
|
|
3.10.4Altitude
Operating | |
|
|
Nonoperating | |
|
|
Momentus Product Manual, Rev. D | 13 |