Performance

Reference

Test

Description

level

standard

 

 

 

 

Electrostatic discharge

Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV

B

EN 61000-4-2: 95

 

 

 

 

Radiated RF immunity

80 to 2,000 MHz, 10 V/m,

A

EN 61000-4-3: 96

 

80% AM with 1 kHz sine

 

ENV 50204: 95

 

900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz

 

 

 

 

 

 

Electrical fast transient

± 1 kV on AC mains, ± 0.5 kV on external I/O

B

EN 61000-4-4: 95

 

 

 

 

Surge immunity

± 1 kV differential, ± 2 kV common, AC mains

B

EN 61000-4-5: 95

 

 

 

 

Conducted RF immunity

150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz

A

EN 61000-4-6: 97

 

sine

 

 

 

 

 

 

Power Frequency H-field

1 A/m, 50Hz/60Hz, 3 axes

A

EN 61000-4-8: 97

immunity

 

 

 

 

 

 

 

Voltage dips, interrupts

30% Reduction for 25 cycles

C

EN 61000-4-11: 94

 

>95% Reduction for 250 cycles

C

 

 

>95%, 0.5 cycles

B

 

 

 

 

 

16

Momentus 7200 FDE.1 SATA Product Manual, Rev. A

Page 22