59

Number of sectors transferred during a Read Multiple or Write

xxxxH

 

Multiple command

 

 

 

 

60–61

Total number of user-addressable LBA sectors available

ST910021A = 195,371,568

 

(see Section 2.2 for related information)

ST980825A = 156,301,488

 

ST96023A = 117,210,240

 

 

 

 

ST94015A = 78,140,160

 

 

 

62

Retired

0000H

 

 

 

63

Multiword DMA active and modes supported (see note follow-

xx07H

 

ing this table)

 

 

 

 

64

Advanced PIO modes supported (modes 3 and 4 supported)

0003H

65

Minimum multiword DMA transfer cycle time per word (120

0078H

 

nsec)

 

 

 

 

66

Recommended multiword DMA transfer cycle time per word

0078H

 

(120 nsec)

 

 

 

 

67

Minimum PIO cycle time without IORDY flow control (240

00F0H

 

nsec)

 

 

 

 

68

Minimum PIO cycle time with IORDY flow control (120 nsec)

0078H

69–74

ATA-reserved

0000H

75

Queue depth

0000H

76–79

ATA-reserved

0000H

80

Major version number

007EH

81

Minor version number

0000H

82

Command sets supported

346BH

83

Command sets supported

7D01H

84

Command sets support extension

4003H

85

Command sets enabled

34xxH

86

Command sets enabled

3xxxH

87

Command sets enable extension

4003H

88

Ultra DMA support and current mode

xx3FH

 

(see note following this table)

 

 

 

 

89

Security erase time

0000H

 

 

 

90

Enhanced security erase time

0000H

 

 

 

91

Advanced power management value

0040H

 

 

 

92

Master password revision code

FFFEH

 

 

 

93

Hardware reset value (see description following this table)

xxxxH

 

 

 

94

Auto acoustic management setting

xxxxH

 

 

 

95–127

ATA-reserved

0000H

 

 

 

128

Security status

0001H

 

 

 

129–159

Seagate-reserved

xxxxH

 

 

 

26

Momentus 7200.1 PATA Product Manual, Rev. C

Page 32
Image 32