• Idle and Standby timers

Each time the drive performs an Active function (read, write or seek), the standby timer is reinitialized and begins counting down from its specified delay times to zero. If the standby timer reaches zero before any drive activity is required, the drive makes a transition to Standby mode. In both Idle and Standby mode, the drive accepts all commands and returns to Active mode when disc access is necessary.

2.10Environmental specifications

2.10.1Ambient temperature

Ambient temperature is defined as the temperature of the environment immediately surrounding the drive. Actual drive case temperature should not exceed 65°C (149°F) within the operating ambient conditions.

Above 1,000 feet (305 meters), the maximum temperature is derated linearly by 1°C every 1000 feet.

Operating:

5° to 55°C (41° to 131°F)

 

 

Nonoperating:

–40° to 70°C (–40° to 158°F)

 

 

2.10.2Temperature gradient

Operating

20°C per hour (68°F per hour max), without condensation

 

 

Nonoperating

30°C per hour (86°F per hour max), without condensation

 

 

2.10.3Humidity

2.10.3.1Relative humidity

Operating

5% to 90% noncondensing (30% per hour max)

 

 

Nonoperating

5% to 95% noncondensing (30% per hour max)

 

 

2.10.3.2Wet bulb temperature

Operating

30°C

(86°F max)

 

 

 

Nonoperating

40°C

(104°F max)

 

 

 

2.10.4Altitude

Operating

–304.8 m to 3,048 m (–1,000 ft to 10,000+ ft)

 

 

Nonoperating

–304.8 m to 12,192 m (–1,000 ft to 40,000+ ft)

 

 

Momentus 5400.2 SATA Product Manual, Rev. C

11

Page 17
Image 17
Seagate ST9100824AS, ST98823AS, ST96812AS, ST94813AS, ST93811AS, ST9120821AS manual Environmental specifications