Table 5: | DC power requirements for ST9300605FC model |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| 2Gb |
| 4Gb |
|
|
|
|
|
|
|
|
|
|
|
| Notes | (Amps) | (Amps) | (Amps) | (Amps) |
|
|
|
|
|
|
|
|
Voltage |
|
|
| +5V | +12V [2] | +5V | +12V [2] |
|
|
|
|
|
|
| |
Regulation |
| [6] | ±5% | ±5% [2] | ±5% | ±5% [2] | |
|
|
|
|
|
|
| |
Avg idle current DC |
| [1] [8] | 0.36 | 0.15 | 0.38 | 0.15 | |
|
|
|
|
|
|
| |
Advanced Idle Current |
|
|
|
|
|
| |
| Idle_A | 3σ |
| 0.38 | 0.16 | 0.39 | 0.16 |
| Idle_B | 3σ |
| 0.26 | 0.15 | 0.27 | 0.15 |
| Idle_C | 3σ |
| 0.26 | 0.09 | 0.27 | 0.09 |
| Standby | 3σ |
| 0.26 | 0.06 | 0.27 | 0.06 |
|
|
|
|
|
|
| |
Maximum starting current |
|
|
|
|
|
| |
| (peak DC) DC | 3σ | [4] | 0.61 | 0.89 | 0.63 | 0.89 |
| (peak AC) AC | 3σ | [4] | 0.95 | 1.54 | 0.99 | 1.52 |
|
|
|
|
|
|
| |
Delayed motor start (max) DC | 3σ | [1] [5] | 0.57 | 0.06 | 0.58 | 0.06 | |
|
|
|
|
|
|
| |
Peak operating current (random read): |
|
|
|
|
|
| |
| Typical DC |
| [1] [7] | 0.45 | 0.35 | 0.47 | 0.35 |
| Maximum DC | 3σ | [1] | 0.47 | 0.37 | 0.49 | 0.37 |
| Maximum (peak) DC | 3σ |
| 1.23 | 1.48 | 1.16 | 1.46 |
|
|
|
|
|
|
| |
Peak operating current (random write) |
|
|
|
|
|
| |
| Typical DC |
|
| 0.51 | 0.33 | 0.52 | 0.33 |
| Maximum DC | 3σ |
| 0.53 | 0.36 | 0.54 | 0.36 |
| Maximum (peak) DC | 3σ |
| 1.06 | 1.48 | 1.06 | 1.51 |
|
|
|
|
|
|
| |
Peak operating current (sequential read) |
|
|
|
|
|
| |
| Typical DC |
|
| 0.81 | 0.14 | 0.83 | 0.14 |
| Maximum DC | 3σ |
| 0.86 | 0.15 | 0.87 | 0.14 |
| Maximum (peak) DC | 3σ |
| 1.12 | 0.32 | 1.15 | 0.32 |
|
|
|
|
|
|
| |
Peak operating current (sequential write) |
|
|
|
|
|
| |
| Typical DC |
|
| 0.89 | 0.14 | 0.91 | 0.14 |
| Maximum DC | 3σ |
| 0.94 | 0.15 | 0.95 | 0.14 |
| Maximum (peak) DC | 3σ |
| 1.20 | 0.32 | 1.19 | 0.30 |
|
|
|
|
|
|
|
|
[1]Measured with average reading DC ammeter. Instantaneous +12V current peaks will exceed these values. Power supply at nominal voltage. N (number of drives tested) = 6, 35 Degrees C ambient.
[2]For +12 V, a
[3]See +12V current profile in Figure 5.
[4]See +12V current profile in Figure 6.
[5]This condition occurs when the Motor Start option is enabled and the drive has not yet received a Start Motor com- mand.
[6]See paragraph 7.3.1, "Conducted noise immunity." Specified voltage tolerance includes ripple, noise, and transient response.
[7]Operating condition is defined as random 8 block reads.
[8]During idle, the drive heads are relocated every 30 seconds to a random location within the band from
26 | Savvio 10K.5 FC Product Manual, Rev. D |