Table 5:

DC power requirements for ST9300605FC model

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2Gb

 

4Gb

 

 

 

 

 

 

 

 

 

 

 

 

Notes

(Amps)

(Amps)

(Amps)

(Amps)

 

 

 

 

 

 

 

 

Voltage

 

 

 

+5V

+12V [2]

+5V

+12V [2]

 

 

 

 

 

 

 

Regulation

 

[6]

±5%

±5% [2]

±5%

±5% [2]

 

 

 

 

 

 

 

Avg idle current DC

 

[1] [8]

0.36

0.15

0.38

0.15

 

 

 

 

 

 

 

Advanced Idle Current

 

 

 

 

 

 

 

Idle_A

3σ

 

0.38

0.16

0.39

0.16

 

Idle_B

3σ

 

0.26

0.15

0.27

0.15

 

Idle_C

3σ

 

0.26

0.09

0.27

0.09

 

Standby

3σ

 

0.26

0.06

0.27

0.06

 

 

 

 

 

 

 

Maximum starting current

 

 

 

 

 

 

 

(peak DC) DC

3σ

[4]

0.61

0.89

0.63

0.89

 

(peak AC) AC

3σ

[4]

0.95

1.54

0.99

1.52

 

 

 

 

 

 

 

Delayed motor start (max) DC

3σ

[1] [5]

0.57

0.06

0.58

0.06

 

 

 

 

 

 

 

Peak operating current (random read):

 

 

 

 

 

 

 

Typical DC

 

[1] [7]

0.45

0.35

0.47

0.35

 

Maximum DC

3σ

[1]

0.47

0.37

0.49

0.37

 

Maximum (peak) DC

3σ

 

1.23

1.48

1.16

1.46

 

 

 

 

 

 

 

Peak operating current (random write)

 

 

 

 

 

 

 

Typical DC

 

 

0.51

0.33

0.52

0.33

 

Maximum DC

3σ

 

0.53

0.36

0.54

0.36

 

Maximum (peak) DC

3σ

 

1.06

1.48

1.06

1.51

 

 

 

 

 

 

 

Peak operating current (sequential read)

 

 

 

 

 

 

 

Typical DC

 

 

0.81

0.14

0.83

0.14

 

Maximum DC

3σ

 

0.86

0.15

0.87

0.14

 

Maximum (peak) DC

3σ

 

1.12

0.32

1.15

0.32

 

 

 

 

 

 

 

Peak operating current (sequential write)

 

 

 

 

 

 

 

Typical DC

 

 

0.89

0.14

0.91

0.14

 

Maximum DC

3σ

 

0.94

0.15

0.95

0.14

 

Maximum (peak) DC

3σ

 

1.20

0.32

1.19

0.30

 

 

 

 

 

 

 

 

[1]Measured with average reading DC ammeter. Instantaneous +12V current peaks will exceed these values. Power supply at nominal voltage. N (number of drives tested) = 6, 35 Degrees C ambient.

[2]For +12 V, a –10% tolerance is allowed during initial spindle start but must return to ±5% before reaching 9,936 RPM. The ±5% must be maintained after the drive signifies that its power-up sequence has been completed and that the drive is able to accept selection by the host initiator.

[3]See +12V current profile in Figure 5.

[4]See +12V current profile in Figure 6.

[5]This condition occurs when the Motor Start option is enabled and the drive has not yet received a Start Motor com- mand.

[6]See paragraph 7.3.1, "Conducted noise immunity." Specified voltage tolerance includes ripple, noise, and transient response.

[7]Operating condition is defined as random 8 block reads.

[8]During idle, the drive heads are relocated every 30 seconds to a random location within the band from three-quarters to maximum track