MODEL INFORMATION

5

Following the wiring diagram, route wires on a 12VDC circuit using good electrical practice.

A.Connect the red wire through a 1/2-amp fuse (not supplied), to the positive DC source.

B.Connect the white wire from the red LED to one of the white wires on the Float Switch Assembly.

C.Connect the remaining white wire from the Float Switch Assembly to the negative DC source.

6

Place the Switch Assembly into the tank with the gasket in place. Drive four No. 8 x 3/4” mounting screws using care to tighten evenly. DO NOT OVER-TIGHTEN.

7

Mount the Indicator Assembly. Fasten with the two No.4 x 1/2” screws provided.

MODEL INFORMATION

SPECIFICATIONS

Part Number

Description

Average Current Consumption: 0.016 amps

313000312

TankWatch 1 Panel, Float Assembly

 

Dometic Corporation • Sanitation Systems

13128 State Rt. 226, P.O. Box 38

Big Prairie, OH 44611-0038 USA

330-496-3211

1-800-321-9886 • Fax: 330-496-3097

® Registered; ™ Trademark of Dometic Corporation

© Dometic Corporation

600340507 4/03