DIMENSIONAL SPECIFICATIONS

TROUBLESHOOTING GUIDE

 

 

Problem

Possible Cause

Service Instructions

6. Pump running too slow,

a. Improper voltage.

a. Check input power for low voltage.

 

overheating, blowing

b. Loose or broken electrical

b. Tighten or reconnect wires.

 

fuses or circuit breakers.

wiring.

c. Wire size too small – check

 

 

 

c. Improper wire size.

 

 

 

 

electrical diagram for proper wire

 

 

 

 

size for voltage of pump used.

 

 

 

d. Gear motor worn or defective.

d. Check motor and replace if necessary.

 

 

 

e. Tank is overfilled – air pump

e. Disassemble air pump and empty out water.

 

 

 

forced to pump water.

 

 

 

 

 

 

 

 

7.

Difficulty in emptying

a. The dockside pump is very

a. Turn off the power to the VHT system. Flush

 

waste from holding

weak and has low suction

the toilet, releasing all the stored vacuum. Begin

 

tank.

capability.

pumping out. Repeat flushing if the dockside pump

 

 

 

 

begins having trouble emptying out the waste.

 

 

 

 

 

 

8.

Pump emits odor.

a. Worn, torn, or punctured

a. Replace pump diaphragm.

 

 

 

pump diaphragm.

 

 

 

 

 

 

 

 

9.

System emits odor.

a. Check for improper flexible

a. Replace hose where necessary. Replacement

 

 

 

hose.

hose should be marked “OdorSafe.”

 

 

 

 

 

 

 

 

Important Owner Information: OdorSafe® Sanitation Hose is formulated for transfer of sanitary waste

 

 

 

only. Do not allow the following items in system: Strong acids or caustic chemicals (example: drain open-

 

 

 

ers), petroleum solvents or fuels, alcohol-based products (example: alcohol-based antifreeze), pine oil-

 

 

 

based products (example: Pinesol® cleaner). Use of products containing these substances will void

 

 

 

warranty on hose.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIMENSIONAL SPECIFICATIONS