Sears 200.71495 owner manual Problem Alarm is On, Troubleshooting

Models: 200.71495

1 10
Download 10 pages 37.21 Kb
Page 8
Image 8

9.troubleshooting

Problem: Alarm is On

REASON

SOLUTION

Display shows

 

. Device has a short

Cycle inverter power OFF and ON.

SC

circuit or demands

 

 

too much surge

If problem persists, use a larger inverter

power.

 

 

 

 

 

 

or a smaller device

 

 

 

 

 

 

Remove defective device.

 

 

 

 

 

 

Call 1-800-SEARS-64 (1-800-732-7764)

 

 

 

 

 

 

for troubleshooting assistance.

Display shows

 

 

 

. 12 Volt battery is

Recharge/replace low battery.

Lo b

too low.

 

 

 

 

 

 

 

Display shows Voltage in between

12 Volt battery is low.

10.5 and 11.0 Volts.

Recharge/replace low battery.

 

 

 

 

 

 

 

 

 

 

 

 

Inverter will automatically shut off after

 

 

 

 

 

 

battery voltage reaches 10.5 volts.

Display shows

 

 

 

. DC Voltage in is

If in a vehicle, repair/replace the alterna-

Hi b

too high.

 

 

 

tor or charging system.

 

 

 

 

 

 

Use a properly sized and rated 12 Volt

 

 

 

 

 

 

battery.

 

 

 

 

 

 

If input voltage returns to 15 volts or less,

 

 

 

 

 

 

the inverter will automatically restart.

 

 

 

Display shows

HiP. Device demands

Cycle inverter power OFF and ON.

more than 750

Watts continuous

If problem persists, use a larger inverter

power.

 

 

 

 

 

 

or a smaller device.

Display shows

 

 

. Inverter is too hot.

Increase ventilation to inverter.

HoT

 

 

 

 

 

 

Move inverter to a cooler area.

 

 

 

 

 

 

Reduce the power consumption of the

 

 

 

 

 

 

device.

 

 

 

 

 

 

Inverter will automatically reset after

 

 

 

 

 

 

cooling.

 

 

Problem: Inverter Does Not Turn On

REASON

SOLUTION

Poor contact at terminals.

Unplug and reinsert Power Inverter 750.

 

 

Fuse is blown.

A blown fuse is usually caused by re-

 

 

 

 

 

 

verse polarity or a short circuit within the

 

 

 

 

 

 

inverter. The fuse is not user replaceable.

Inverter may be defective.

Call 1-800-SEARS-64 (1-800-732-7764)

 

 

 

 

 

 

for troubleshooting assistance.

 

 

 

 

 

 

6