Sears 390.252158 owner manual Testing for Bag Leakage, Removing Motor for Service

Models: 390.252158

1 16
Download 16 pages 48.81 Kb
Page 8
Image 8

MAINTENANCE

NOTICE: DO not overtighten; you may twist studs off of

tank. If you have a torque wrench, tighten to 85 inch-

pounds torque.

18.Stand tank on feet and reconnect piping.

19.Recharge tank to proper air pressure (see Page 5).

20.Reconnect hoses and pressure switch tube; prime pump (see Page 6).

Air Valve Replacement

1.Follow steps 1 through 5 under _Vinyl Bag Removal", Page 7.

2.Cut valve off as close to tank as possible. Push remaining portion back into tank.

3.Tip tank on end and BE SURE all water is drained from bag.

4.Carefully remove bag ring from lip on tank opening and push bag ring back into tank; reach in around it and re- move cut off portion of valve from tank.

5.Wipe a thin film of soapy solution on replacement valve and from inside tank insert in hole in top of tank.

6.Pull valve through hole with pliers or a valve tool (avail-

able at your local filling station or Automotive Center).

7.Follow steps 14 through 20 under "Vinyl Bag Removal", Page 7, to reinstall bag in tank.

Testing for Bag Leakage

1.Follow steps 1 through 4 under "Vinyl Bag Removal", Page 7.

2.Tip tank on end, vane down. Be careful not to break valve!

3.If bag leaks, water will run out of valve. If so, replace bag

as instructed above.

DISASSEMBLY AND

ASSEMBLY OF PUMP

I

I _.WARNING JRtsk of electric shock. Ground unit and

disconnect power before attempting any work on

pomp or motor.

Your Sears pump is designed for ease in servicing. Should

repair or replacement of the motor or seal be needed, the

pump and piping do not need to be disconnected or dis- tuthed.

1.Disassemble pump as follows:

A.Disconnect power.

B.Drain pump by opening drain cock. Remove pressure switch tubing from fitting on top of pump.

_WARNING]To avoid serious injory,release all

pressure fi'om system before attempting to remove clamp from pump.

C. Remove clamp, Key No. 10, Page 12.

D. Remove pump base motmting bolts. Motor assembly and back half assembly of pump can he pulled away from front half.

E. Remove "O" rings.

2.Reassembly of pump.

A. Clean =O" rings and "O" ring grooves.

B.Lubricate =O" rings with petroleum jelly, and place in grooves.

C.Slide pump halves together.

D.Clean inside of clamp. Place clamp around pump halves. Alternately tighten clamp screw and tap clamp around outside with plastic mallet. This will insure proper seating of "O" ring and clamp.

E. Assemble base mounting bolts. Connect pressure switch tubing and close drain cock.

F. Prime pump and turn on power. G. Check for leaks.

Removing Motor for Service

and Replacing Shaft Seal

If it is he4:_essary to separate motor and seal plate, always re-

place the shaft seal. We suggest you purchase this item, UlO94SA, and have it on hand for future use.

NOTICE: The seal consists of two parts, a rotating member and a ceramic seat. The surfaces of the seal are easily dam-

aged. Read instructions carefully.

1. Disassemble pump per instructions above.

2.Remove diffuser and impeller as follows (Key Nos. 8 and 9, Page 12).

A.Remove screws holding diffuser.

B.Loosen two screws and remove motor canopy from motor.

C.Place 7/16" open end wrench on motor shaft flat.

D.Turn impeller counterclockwise when facing it.

3.Remove pump back half from motor by unscrewing four

(4)nuts. Pry back half off motor by inserting two (2)

screwdrivers between the back pump half and the motor flange. This will force rotating portion of seal off shaft. See Figure 5.

4750194

Figure 5

8

Page 8
Image 8
Sears 390.252158 owner manual Testing for Bag Leakage, Removing Motor for Service