![](/images/new-backgrounds/1013547/135475x1.webp)
SAFETY INSTRUCTIONS (Continued)
6. Disconnect electrical power source before installing or working on pump.
7.Ground pump with a ground wire run from grounding
lug on motor to a grounded lead in the service panel.
8.Line voltage and frequency of electrical power supply must agree with motor nameplate.
9.Use of fuses or wire smaller than size recommended in
owner's manual can cause overheating, possible fires, and will void warranty.
TABLE I - Pump Performance (In Gallons per Minute)
NOTE: This system is designed for pumping depths of 20 feet or less.
Pump |
|
|
| Discharge | Pumping Depth in Feet | |||
Model | Description | Suct. | Disch. | Pressure PSI | 5' | 10' | 15' | 20' |
390.252158 | 112 HP S.W. Jet | 1" | 40 | 8.2 | 7.3 | 6.2 | 5.0 |
|
|
| BASIC TOOLS AND MATERIALS NEEDED |
| |||||||
Plastic Pipe | Installation |
|
|
|
|
|
|
| |||
Tools |
|
|
| Materials |
|
|
|
|
| ||
Pipe | Wrenches |
|
|
| Plastic | Pipe | and | Fittings (as required to complete job). |
| ||
Screwdriver |
|
|
|
|
|
|
|
|
|
| |
Knife | or Saw | to Cut | Plastic Pipe | Teflon | Tape | (DO | NOT | use joint compound | on plastic | fittings). | |
Tire | Pressure | Gauge |
|
|
|
|
|
|
|
|
|
Galvanized | Steel | Pipe | Installation |
|
|
|
|
|
| ||
Tools |
|
|
| Materials |
|
|
|
|
| ||
Pipe | Wrenches |
|
|
| Galvanized | Pipe | and Fittings (as required | to complete | job). | ||
Screwdriver |
|
|
|
|
|
|
|
|
|
| |
Pipe | Cutting | and Threading | Tools | Pipe Joint Compound | or Teflon Tape |
|
| ||||
Tire | Pressure | Gauge |
|
|
|
|
|
|
|
|
|
MAJOR COMPONENTS
Impeller and Jet
Impeller turns with motor shaft, causing water to fly out
from its rim by centrifugal force. Impeller rotation creates a vacuum which pulls in more water. Part of the water is di- verted back to the jet where it passes through the nozzle and venturi. This creates more vacuum to draw in more water.
In shallow wells (less than 20 feet deep), the vacuum cre-
ated at the pump is_enough to pull water to toe pump.
Therefore, for shallow
Pre-Charged Tank
The tank serves two functions, it provides a reservoir of
water under pressure and maintains a cushion of air pres-
sure to prevent pipe hammering and possible damage to
plumbing components. When water is drawn off through
the house fixtures, the pressure in the tank is lowered and the pump starts.
AND WHAT THEY DO
Pressure Switch
The pressure switch provides for automatic operation.
Pump starts when pressnre drops to 40 pounds and stops when pressure reaches 60 pounds.
Check Valve or Foot Valve
This pump is equipped with a
check valve as close to well as possible o_ well point in- stallations. A foot valve must be installed in the well on dug or cased wells. See Figures ZA and 2B, Page 4. For long hor- izontal pipe runs, install check valve as close to well as pos- sible (all types of wells).
3